Copper Units of Pressure (CUP) estimate firearm chamber pressure from the permanent deformation of calibrated copper cylinders. Unlike modern piezoelectric sensors, copper crushers do not measure instantaneous pressure; their deformation reflects the combined effects of peak pressure, loading duration, impulse, strain-rate sensitivity, and dynamic plastic flow. Conformal ballistic sensors, by contrast, provide time-resolved pressure histories that distinguish peak pressure, rise time, and impulse. This study examines the dynamic response of copper crushers using drop-tower testing and compares the resulting deformation with piezoelectric force measurements. The results demonstrate that crusher deformation is dependent on both loading magnitude and the manner in which the load is applied. The information presented in this study are the first steps of defining a pressure vs impulse response curve for the copper crusher deformation. Future studies will explore different loading conditions from ballistic chamber pressure and explosive loading.