Kinetic-energy non-lethal weapons (KENLW) may cause severe head injuries, highlighting the need for standardized assessment methodologies. NATO AEP-103 defines requirements for validating experimental surrogates; however, its implementation is constrained by the limited availability and reproducibility of the B&T SIR-X reference projectile. This study investigates an alternative approach based on a reusable aluminum projectile and the development of a simplified surrogate. The Blunt Load Sensing Headform (BLSH) was first validated according to AEP-103 using available SIR-X projectiles. The aluminum projectile was subsequently shot on the validated BLSH to establish a reference database. A surrogate combining a characterized force wall with a polyurethane damping pad was developed and assessed through signal consistency, impulse–momentum agreement, similarity with BLSH responses, and repeatability analyses. A 10 mm VytaFlex 45 flat-shaped damping pad configuration showed the best agreement, providing a promising solution for AEP-103-compliant KENLW head impact assessment.