Open Access Open Access  Restricted Access Subscription Access

HEAD SURROGATE USE AND DEVELOPMENT FOR KINETIC ENERGY NON-LETHAL WEAPON INJURY ASSESSMENT

Cyril Robbe, Eloïse Sarge, Anca Andrei, Alexandre Papy

Abstract


Kinetic-energy non-lethal weapons (KENLW) may cause severe head injuries, highlighting the need for standardized assessment methodologies. NATO AEP-103 defines requirements for validating experimental surrogates; however, its implementation is constrained by the limited availability and reproducibility of the B&T SIR-X reference projectile. This study investigates an alternative approach based on a reusable aluminum projectile and the development of a simplified surrogate. The Blunt Load Sensing Headform (BLSH) was first validated according to AEP-103 using available SIR-X projectiles. The aluminum projectile was subsequently shot on the validated BLSH to establish a reference database. A surrogate combining a characterized force wall with a polyurethane damping pad was developed and assessed through signal consistency, impulse–momentum agreement, similarity with BLSH responses, and repeatability analyses. A 10 mm VytaFlex 45 flat-shaped damping pad configuration showed the best agreement, providing a promising solution for AEP-103-compliant KENLW head impact assessment.


DOI
10.12783/ballistics26/37659

Full Text:

PDF

Refbacks

  • There are currently no refbacks.