OPTIMIZATION OF A DUAL-CAMERA HIGH-SPEED SETUP FOR WOUND BALLISTICS MEASUREMENTS
Abstract
Wound ballistics relies on quantifying the temporary cavity formed in tissue simulants. High-speed imaging of ballistic gelatine is one approach to measure it, limited by optical errors: refraction at the gelatine–air interface, lens distortion which produces a negligible error and a conversion factor calibrated at a single depth. Snell's law shows that bending at the gelatine surface explains only about a third of the measured error; the remainder is attributed to light that continues to bend along its path through the block. The correction is therefore calibrated against physical references and grows in proportion to depth. Correcting either error requires the depth of each measured point, which only a second, orthogonal camera supplies. Across twelve 5.56 × 45 mm SS109 shots, the maximum cavity height is corrected by −3.5 % to −4.1 %, and by −3.6 % to −4.4 % along a single cavity.